Minicom Advanced Systems 5UM20114 User Manual

Page of 87
OPERATING GUIDE
.
 
6
 
 
Figure 3 The Hyperterminal 
6. Press Enter. Some device information and a prompt appear.  
7. Type config and press Enter. Configuration questions appear. DHCP can be 
enabled or disabled. You can change the IP address, net mask and default 
gateway. Pressing Enter without entering values keeps the default values. To 
contact Smart 16 IP from outside the LAN configure a gateway. To remove an 
already configured gateway, type 0.0.0.0. 
  The last question – enable IP access control – concerns switching IP packet 
filtering on or off. This can re-enable access to Smart 16 IP after an incorrect 
IP access configuration has been activated. Page 44 has more information on 
IP access control. 
8.  Confirm the settings, Smart 16 IP resets the configuration.  
 
(B) Use a crossover Ethernet cable to connect the Smart 16 IP to the computer 
back-to-back.  
Set the IP address of the computer to 192.168.1.20 and type 192.168.1.22 into the 
Address box of the web interface to carry out the IP configuration.  
5. Mouse, Keyboard and Video configuration  
The correct operation of the client mouse depends on the following two settings. 
Smart 16 IP mouse setting  
To make the remote keyboard and mouse work properly the Smart 16 IP settings 
for the host's mouse and keyboard types must be correct. Check the settings in the 
Smart 16 IP Web interface. See page 20.