Moxa Technologies 405A SERIES User Manual

Page of 86
EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-26
Coupling—Mode 
Indicates either NoneDual Homing, or Ring Coupling. 
Coupling—Coupling Port status 
Indicates either Primary, or Backup
Explanation of “Settings” Items 
Redundancy Protocol 
Setting 
Description 
Factory Default 
Turbo Ring 
Select this item to change to the 
Turbo Ring configuration page. 
Turbo Ring V2 
Select this item to change to the 
Turbo Ring V2 configuration page. 
RSTP (IEEE 
802.1W/1D) 
Select this item to change to the 
RSTP configuration page. 
None 
Ring redundancy is not active 
None 
Enable Ring 1 
Setting 
Description 
Factory Default 
Enabled 
Enable the Ring 1 settings 
Disabled 
Disable the Ring 1 settings 
Not checked 
Enable Ring 2* 
Setting 
Description 
Factory Default 
Enabled 
Enable the Ring 2 settings 
Disabled 
Disable the Ring 2 settings 
Not checked 
*You should enable both Ring 1 and Ring 2 when using the Dual-Ring architecture. 
Set as Master 
Setting 
Description 
Factory Default 
Enabled 
Select this EDS as Master 
Disabled 
Do not select this EDS as Master 
Not checked 
Redundant Ports 
Setting 
Description 
Factory Default 
1st Port 
Select any port of the EDS to be 
one of the redundant ports. 
EDS-405A: port 4 
EDS-408A: port 7 
2nd Port 
Select any port of the EDS to be 
one of the redundant ports. 
EDS-405A: port 5 
EDS-408A: port 8 
Enable Ring Coupling 
Setting 
Description 
Factory Default 
Enable 
Select this EDS as Coupler 
Disable 
Do not select this EDS as Coupler 
Not checked