Troubleshooting Switched Ethernet Connectivity
Verify Switch Health
OmniSwitch Troubleshooting Guide
September 2005
page 2-7
Verify Switch Health
If source learning appears to be not working correctly, verify the health of the switch with the show health, 
and show health slot commands. Be sure to run the latter command on all necessary NIs. Any variables 
that have reached or exceeded their limit value could cause forwarding problems on the switch. In this 
case please contact Technical Support. For more detailed source learning trouble shooting, please see 
-> show health
* - current value exceeds threshold
Device                          1 Min  1 Hr  1 Hr
Resources          Limit   Curr   Avg    Avg   Max
-----------------+-------+------+------+-----+----
Receive              80     00     00    00    00
Transmit/Receive     80     00     00    00    00
Memory               80     39     39    39    39
Cpu                  80     02     02    02    03
Temperature Cmm      50     39     39    39    39
Temperature Cmm Cpu  50     31     31    31    31
-> show health 5
* - current value exceeds threshold
Slot  05                        1 Min  1 Hr  1 Hr
Resources          Limit   Curr   Avg    Avg   Max
-----------------+-------+------+------+-----+----
Receive              80     00     00    00    01
Transmit/Receive     80     01     01    01    01
Memory               80     16     16    16    16
Cpu                  80     29     33    32    35
Verify ARP
If everything checked appears to be valid, verify that this is not an ARP problem. On the end stations 
involved, enter a static mac address for the device it is trying to communicate with. If connectivity is 