Fiber Optic Transceivers
The L/A LEDs on the AT-SBx81GS24a and AT-SBx81XS6 Line Cards are 
solid or flashing green when ports on fiber optic transceivers have links to 
end nodes. If a transceiver is cabled to an end node but the L/A LED is off, 
try the following:
If all of the L/A LEDs on the line cards in the chassis are off, try 
pressing the eco-friendly button on the active master controller 
card to turn on the LEDs.
Check that the fiber optic transceiver is firmly inserted into the slot 
on the line card.
Check that both ends of the fiber optic cable are securely 
connected to the ports on the transceiver and end node.
Verify that the end node is powered on and operating properly.
Review the operating specifications of the fiber optic transceiver 
and end node to verify that the devices have the same speed and 
duplex mode.
Check that the operating specifications, including wavelength and 
maximum operating distance, of the transceiver are compatible 
with the fiber optic port on the end node.
Make sure that you are using the appropriate type of fiber optic 
cable and that the cable length does not exceed the allowed 
maximum distance. The cable specifications for the transceivers 
are provided in the installation instructions that ship with the 
modules.
Use a fiber optic tester to test the whether the optical signal is too 
weak (i.e., sensitivity) or too strong (i.e., maximum input power). 
The operating specifications of the fiber optic transceivers are 
shipped with the units.
Try replacing the fiber optic cable.
Check the two strands of the fiber optic cable to be sure that the 
receive fiber connector is connected to the transmit connector on 
the remote end node, and that the transmit fiber connector is 
connected to the receive connector on the end node.