Chapter 10: Replacing Modules
224
Replacing the AT-SBx81CFC400 Controller Fabric Card
This section contains the procedure for replacing a controller card in the 
chassis.
Note
This procedure requires the following tool:
#2 Phillips-head screwdriver (not provided)
The controller card is hot swappable and can be removed while the 
chassis is powered on.
Here are the general steps if the chassis has only one controller card and 
that card has failed such that it is no longer responding to management 
commands and the Ethernet line cards have stopped forwarding traffic:
1. Power off the chassis.
2. Remove the failed controller card. Refer to the instructions in this 
section.
3. Install the new controller card. You may install the new controller card 
in the same slot as the failed card or in the other controller card slot. 
For instructions, refer to “Installing the AT-SBx81CFC400 Controller 
Fabric Card” on page 112.
4. Power on the chassis.
5. Restore the configuration to the Ethernet line and controller cards by 
uploading the latest archived copy of the configuration file for the 
chassis to the new controller card. If you do not have an archived copy 
of the configuration settings of the chassis, restore the configuration 
manually.
Here are the general steps If the chassis has two controller cards and one 
cards has failed:
1. If the chassis is powered off, power it on.