Allied Telesis AT-8100S/24 User Manual

Page of 138
Chapter 9: Adding or Removing Switches
120
Removing or Replacing the Master Switch
This procedure is divided into the following phases:
The procedures should be performed in the order presented here.
Here are the guidelines to removing or replacing the master switch:
When you power off the master switch, the member switch that 
has the lowest ID number of the remaining switches automatically 
assumes the role of the master switch of the stack.
The new master switch should be the same model as the current 
master switch. Otherwise, the operations of the stack m ay be 
unpredictable. For instance, you should not replace an AT-8100S/
16F8-SC Switch with an AT-8100S/24 Switch.
You should not connect the new master switch to the stack until 
after you have installed the stack’s configuration file on it. 
Otherwise, the entire stack configuration may be lost. The 
procedure for this is in “Uploading the Active Configuration File” on 
page 121 and
 “Configuring the New Master Switch” on page 125.
In phase 2 it may be necessary to power off the stack. Here are the 
guidelines to determining whether that will be necessary:
You may leave the stack powered on if it is cabled in the duplex-
ring topology, or if it is cabled in the duplex-chain topology and the 
master switch is at the end of the stack.
You should power off the stack if it is wired in the duplex-chain 
topology and the master switch is located between other switches.
Note
For background information on stack topologies, refer to “Stacking 
Port Topologies” on page 55.