Allied Telesis AT-8100S/24 User Manual

Page of 138
Stack Installation Guide for 8100S Series Switches
31
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Power Over
Ethernet
The 10/100Base-TX ports on the AT-8100S/24POE Switch supports 
Power over Ethernet (PoE), which is a standard whereby DC power is 
provided by the switch to network devices over the network twisted pair 
cables. The switch supports PoE (IEEE 802.3af) and PoE+ (IEEE 
802.3at). For background information, refer to “Power Over Ethernet” on 
page 35. 
Cable
Requirements
The cable requirements of the ports are given in Table 6. 
Port Pinouts
Refer to Table 25 on page 134 for the port pinouts of the 10/100Base-TX 
ports.
Table 6. Twisted Pair Cable Requirements for the 10/100Base-TX Ports
Cable Type
10Mbps
100Mbps
Non-
PoE
PoE
PoE+
Non-
PoE
PoE
PoE+
Standard TIA/EIA 568-B-
compliant Category 3 shielded 
or unshielded cabling with 100 
ohm impedance and a 
frequency of 16 MHz.
Yes
No
No
Yes
No
No
Standard TIA/EIA 568-A-
compliant Category 5 shielded 
or unshielded cabling with 100 
ohm impedance and a 
frequency of 100 MHz.
Yes
Yes
No
Yes
Yes
No
Standard TIA/EIA 568-B-
compliant Enhanced Category 
5 (Cat 5e) shielded or 
unshielded cabling with 100 
ohm impedance and a 
frequency of 100 MHz.
Yes
Yes
Yes
Yes
Yes
Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a 
shielded cabling.
Yes
Yes
Yes
Yes
Yes
Yes