Stack Installation Guide for AT-2552XS L2 Data Center Switch
19
AT-DC2552XS
Physical
Description
The AT-DC2552XS L2 Data Center Switch physical description is as 
follows:
AT-DC2552XS Front Panel
The front panel of the AT-DC2552XS is shown in Figure 1 on page 19.
Figure 1. AT-DC2552XS Front Panel View
Blank Covers - When the switch is shipped from the factory, four 
blank covers are installed.
-
Two blank covers for the power supply slots (PS 1/PS 2)
-
Two blank covers for the two fan module slots (FAN 1/FAN 2)
Warning
To insure proper cooling and air flow within the chassis, the blank 
covers should not be removed unless an AT-PWR06 power supply 
module and the AT-FAN06 fan modules are installed in their place.
The power unit slots (PS 1/PS 2) are for the installation of the 
AT-PWR06 power supply module. These slots are located on the 
far right and far left sides of the chassis. 
A second AT-PWR06 power supply module may be installed for 
redundancy, but is not required for normal operation of the switch. 
With a redundant power supply configuration, you can replace one 
of the two power supply modules without turning off the primary 
power supply. Each AT-PWR06 power supply module that is 
installed in the chassis is hot-swappable. Refer to “Installing and 
Replacing AT-PWR06 Power Supply Module” on page 48 fo
r the 
installation procedure.
PS 1 
FAN 1 
FAN 2 
PS 2 
Blank 
Covers
Slot
Slot
Slot
Slot
Fan 1 
LED
Fan 2
LED
[Top of Chassis]