Allied Telesis AT-SBX31GC40 User Manual

Page of 222
SwitchBlade x3112 Installation Guide
37
Automatic MDIX
Detection
The 10/100/1000 Mbps twisted-pair ports on the AT-SBx31GT24, AT-
SBx31GT40, and AT-SBx31GP24 Line Cards are IEEE 802.3ab compliant 
and feature automatic MDIX detection when operating at 10 or 100 Mbps. 
(Automatic MDIX detection does not apply to 1000 Mbps.) This feature 
automatically configures the ports to MDI or MDI-X depending on the 
wiring configurations of the end nodes.
You may not disable automatic MDIX detection on the ports. For automatic 
MDIX detection to work properly, it must also be present on the network 
devices. Ports connected to network devices that do not support automatic 
MDIX detection default to MDIX.
Straight-through
or Crossover
Cabling
Here are the guidelines on whether to use straight-through or crossover 
cables to connect network devices to the line cards:
You may use straight-through cables on ports that are connected 
to network devices that operate at 1000 Mbps.
Table 2.   Twisted Pair Cable for the AT-SBx31GP24 Line Card
Cable Type
10Mbps
100Mbps
1000Mbps
Non-
PoE
PoE
PoE+
Non-
PoE
PoE
PoE+
Non-
PoE
PoE
PoE+
Standard TIA/EIA 568-
B-compliant Category 3 
shielded or unshielded 
cabling with 100 ohm 
impedance and a 
frequency of 16 MHz.
Yes
No
No
Yes
No
No
No
No
No
Standard TIA/EIA 568-
A-compliant Category 5 
shielded or unshielded 
cabling with 100 ohm 
impedance and a 
frequency of 100 MHz.
Yes
Yes
No
Yes
Yes
No
Yes
No
No
Standard TIA/EIA 568-
B-compliant Enhanced 
Category 5 (Cat 5e) 
shielded or unshielded 
cabling with 100 ohm 
impedance and a 
frequency of 100 MHz.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Standard TIA/EIA 568-
B-compliant Category 6 
or 6a shielded cabling.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes