Allied Telesis AT-S111 User Manual

Page of 386
Chapter 19: RMON
254
Alarms
RMON alarms are used to generate alert messages when packet activity 
on designated ports rises above or falls below specified threshold values. 
The alert messages can take the form of messages that are entered in the 
event log on the switch or traps that are send to your SNMP NMS software 
or both.
RMON alarms consist of two thresholds. There is a rising threshold and a 
falling threshold. The alarm is triggered if the value of the monitored 
RMON statistic of the designated port exceeds the rising threshold. The 
response of the switch is to enter a message in the event log, send an 
SNMP trap, or both. The alarm is reset if the value of the monitored 
statistic drops below the falling threshold.
The frequency with which the switch samples the thresholds of an alarm 
against the actual RMON statistic is controlled by a time interval 
parameter. You can adjust this interval for each alarm.
Here are the three components that comprise RMON alarms:
RMON statistics group: A port must have an RMON statistics group 
configured if it is to have an alarm. When you create an alarm, you 
specify the port to which it is to be assigned not by the port number, 
but rather by the ID number of the port’s statistics group. (As explained 
in “Port Statistics” on page 248, statistics groups are also used to 
remotely view port statistics in the RMON portion of the MIB tree.)
RMON event: An event specifies the action of the switch when the 
ingress packet activity on a port crosses a statistical threshold defined 
in an alarm. The choices are to log a message in the event log of the 
switch, send an SNMP trap to an SNMP workstation, or both. Since 
there are only three possible actions and since events can be used 
with more than one alarm, you probably will not create more than three 
events.
Alarm: The last component is the alarm itself. It defines the port 
statistic to be monitored and the rising and falling thresholds that 
trigger the switch to perform an event. The thresholds of an alarm can 
have the same event or different events. The switch supports up to 
eight alarms.
Perform the following procedure to configure RMON alarms.
1. From the main menu on the left side of the page, click the RMON 
folder.
The RMON folder expands.