Allied Telesis AT-SBX31GT24 User Manual

Page of 222
SwitchBlade x3112 Installation Guide
199
AT-SBxPWRSYS1 DC Power Supply
If you suspect a problem with the DC power supply, examine its LEDs. The 
power supply is operating normally when the DC IN and DC OUT LEDs 
are solid green and the Fault LED is off. Possible fault conditions and their 
solutions are described here:
Fault Condition 1: If the DC IN LED is off, the power supply is not receiving 
power, has overheated and been disabled, or has failed and needs to be 
replaced. Try the following:
Verify that the On/Off switch on the power supply is in the On 
position.
Verify that the DC circuit breaker is on.
Verify that the positive and negative power wires are correctly and 
securely connected to the terminal block on the power supply and 
circuit breaker.
Verify that the DC circuit break has power by attaching another 
device to it.
Verify that the power from the DC circuit break is within the 
required levels of the power supply. Refer to “Power 
Specifications” on page 216.
If the chassis is still operating, use the SHOW PSU or SHOW PSU 
ALL command from a local or remote management session to 
determine if the power supply has overheated and shutdown.
Fault Condition 2: If the DC IN LED is solid green but the DC OUT LED is 
off, the power unit is generating insufficient DC power. Replace the power 
supply.
Fault Condition 3: If the Fault LED is solid amber, try the solutions in Fault 
Condition 1. If they do not resolve the problem, replace the power supply.
Note
The power supply is hot swappable. If the chassis has two power 
supplies and one of them fails, you do not have to power off the 
operational power supply to replace the failed unit.
Fault Condition 4: If the LEDs on the power supply indicate normal 
operations but the PSU LED on the active master control card is off or is 
showing a fault condition, try the following suggestions:
The control card may not be able to detect the DC power supply 
because it is not running the most recent version of the 
management software. For instructions on how to verify the