Allied Telesis AT-SBX3165 User Manual

Page of 104
Appendix A: Technical Specifications
100
Environmental Specifications
Operating Temperature:
-0° C to 40° C (32° F to 104° F)
Storage Temperature:
-25° C to 70° C (-13° F to 158° F)
Operating Humidity:
5% to 90% non-condensing
Storage Humidity:
5% to 95% non-condensing
Operating Altitude Range:
Up to 3,000 m (9,843 ft)
Power Specifications
AC Voltage/Frequency Requirements:
100 - 240 VAC, 50/60 Hz
AC Input Current: 
 
AT-SBx3161 System Power Supply
16 A Maximum
 
 
AT-SBx3165 PoE Power Supply
16 A Maximum
Available Power over Ethernet: 
 
 
One PoE Power Supply Installed
1200 W @ 56 VDC
 
IEEE 802.3at Class 4 (30 W /port):
40 ports Maximum
 
IEEE 802.3af Class 3 (15.4 W /port):
77 ports Maximum
 
IEEE 802.3af Class 2 (7.3 W /port):
171 ports Maximum
 
IEEE 802.3af Class 1 (4.0 W /port):
240 ports Maximum
 
 
Two PoE Power Supplies Installed
2400 W @ 56 VDC
 
IEEE 802.3at Class 4 (30 W /port): 
80 ports Maximum
 
IEEE 802.3af Class 3 (15.4 W /port):
155 ports Maximum
 
IEEE 802.3af Class 2 (7.3 W /port):
240 ports Maximum
 
IEEE 802.3af Class 1 (4.0 W /port):
240 ports Maximum
IEEE 802.3af Mode:
Alternative A (MDI)
 
IEEE 802.3at Mode: 
Alternative A (MDI)