Allied Telesis AT-SBX3165 User Manual

Page of 104
SwitchBlade x3112 Installation Guide
91
FAN Fault LED Flashing Amber on AT-SBx31CFC Fabric Control 
Card
Check the FAN System LED on the front panel of the AT-SBx31CFC 
Fabric Control Card for a solid green or flashing amber status. A flashing 
amber status LED indicates a FAULT condition in the AT-SBx31FAN Tray. 
The fan tray is initialized by the software running on the AT-SBx31CFC 
Fabric Control Card. The fan speed is independently adjusted proportional 
to the internal operating temperature. If the fan speed of one or more fans 
falls below a set minimum speed, the fan FAULT condition will occur.
You can obtain specific information for the AT-SBx31CFC Fabric Control 
Card by using the Switchblade x3112 Management Software to note 
specific parameters by entering the following command:
officer SEC>> SHOW FANMODULE
ˆ
Contact Allied Telesis Technical Support for further assistance. Please 
report the AT-SBx31FAN Tray fault condition and the information 
obtained from the SHOW FANMODULE command.
ˆ
If the AT-SBx31FAN Tray needs to be replaced, remove the assembly 
and install a replacement AT-SBx31FAN Tray. Refer to “Replacing the 
AT-SBx31FAN Tray” on page 79.
Note
The AT-SBx31FAN Tray is hot swappable which allows the 
SwitchBlade x3112 to continue to operate while you exchange AT-
SBx31FAN Trays.