Allied Telesis AT-x510-28GPX User Manual

Page of 90
Chapter 5: Powering On the Switch
76
Disabling
VCStack
To disable the VCStack feature to use the switch as stand-alone unit, 
perform the following procedure:
Caution
Disabling the VCStack feature requires resetting the switch. If the 
switch is already connected to a live network, some network traffic 
may be lost.
1. When prompted, enter a user name and password to log on the 
switch. If this is the initial management session of the switch, enter 
“manager” as the user name and “friend” as the password. The user 
name and password are case sensitive.
The local management session starts when the User Exec mode 
prompt, shown in Figure 34. is displayed.
Figure 34. User Exec Mode Prompt
Note
The User Exec mode is the first level in the command mode 
interface. For complete information on the modes and commands, 
refer to the Software Reference for x510 Series Switches, 
AlliedWare Plus Operating System 
from www.alliedtelesis.com.
2. Enter the SHOW STACK command to display the status of the 
VCStack feature. Figure 35 is an example of the command.
Figure 35. SHOW STACK Command
3. Review the following items:
If the Operational Status is “Stacking Hardware Disabled,” the 
VCStack feature is already disabled on the switch and the SFP+ 
stacking slots may be used with regular SFP or SFP+ transceivers.
awplus>
awplus> show stack
Virtual Chassis Stacking summary information
ID
Pending ID
MAC address
Priority
Status
Role
1
-
0015:774f:ed30
128
Ready
Active Master
Operational Status
Standalone Unit
Stack MAC address
0015:774f:ed30
awplus(config)#