Sun Microsystems 120 User Manual

Page of 200
9-6
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
To configure the LOM device to perform an automatic server restart (ASR) after a
lockup, you must enable the
Hardware reset
option as well as the
Watchdog
option. For information about how to do this, see Section 9.2, “Configuring
Automatic Server Restart (ASR)” on page 9-8.
9.1.8
Viewing the Configuration of the LOM Device
(
lom -c
)
To view the settings of all the configurable variables for the LOM device, type:
9.1.9
Viewing All Component Status Data With the
LOM Device’s Configuration Data (
lom -a
)
To view all the status data stored by the LOM device plus the details of the
device’s own configuration, type:
lom -c
LOMlite configuration settings:
serial escape character=#
serial event reporting=default
Event reporting level=fatal, warning & information
Serial security=enabled
Disable watchdog on break=disabled
Automatic return to console=disabled
alarm3 mode=watchdog
firmware version=3.0
firmware checksum=2983
product revision=0.0
product ID=120
#
lom -a