Sun Microsystems 120 User Manual
9-6
Sun Fire V120 and Netra 120 Server User’s Guide • December 2001
●
To configure the LOM device to perform an automatic server restart (ASR) after a
lockup, you must enable the
lockup, you must enable the
Hardware reset
option as well as the
Watchdog
option. For information about how to do this, see Section 9.2, “Configuring
Automatic Server Restart (ASR)” on page 9-8.
Automatic Server Restart (ASR)” on page 9-8.
9.1.8
Viewing the Configuration of the LOM Device
(
(
lom -c
)
●
To view the settings of all the configurable variables for the LOM device, type:
9.1.9
Viewing All Component Status Data With the
LOM Device’s Configuration Data (
LOM Device’s Configuration Data (
lom -a
)
●
To view all the status data stored by the LOM device plus the details of the
device’s own configuration, type:
device’s own configuration, type:
# lom -c
LOMlite configuration settings:
serial escape character=#
serial event reporting=default
Event reporting level=fatal, warning & information
Serial security=enabled
Disable watchdog on break=disabled
Automatic return to console=disabled
alarm3 mode=watchdog
firmware version=3.0
firmware checksum=2983
product revision=0.0
product ID=120
#
# lom -a