10.3
Solutions to Problems You Might
Encounter
Problem: Cannot Set Up a Console Connection to the Server
The Sun Fire V120 and Netra 120 servers’ serial port pinouts are listed in Chapter 6.
Check that they are correct for the device (that is, the terminal or terminal server)
that you are connecting to the server.
FIGURE 10-5
watch-net
Diagnostic Output Message
{0} ok watch-net
Internal loopback test -- succeeded.
Link is -- up
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.................................
FIGURE 10-6
watch-net-all
Diagnostic Output Message
{0} ok watch-net-all
/pci@1f,0/pci@1,1/network@c,1
Internal loopback test -- succeeded.
Link is -- up
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.