FIPS-140-2 Interface 
Physical 
Interface
Logical Interface
Button
Invoke configuration/status function
Status Output
Ethernet
Plaintext status response from console task 
via Telnet
Plaintext status response from web config 
via HTTP
Wireless
Status response from console task via 
Telnet
Status response from web config via HTTP
Serial
Plaintext status response from button push
LEDs
Indicate link and unit error status
Power Interface
Power
Serial
When the module enters an error state, all Data Input and Data Output interfaces are disabled.  If 
an error state is encountered, the LED interface will indicate the error by blinking for several 
seconds, and then the unit will reset.   The unit will not send or receive any data until the reset is 
complete.
The SX-500 performs cryptographic self tests during initialization after power up or a firmware 
induced reset.  Until the self tests are complete, no data input or output interfaces are active.  If 
the self test fails, the unit will enter an error state.
Configuration 
The Cryptographic Officer is responsible for configuring the unit for use in the target environment. 
See Chapter 3 and Appendix A for instructions on configuring the unit.  The peripheral unit 
(usually a PC) being used to configure the SX-500 must be directly connected to the unit via a 
crossover cable or local hub which is not connected to any LAN, WLAN or other larger network. 
This will enable manual transport and electronic entry of secret and private keys (RSA private key 
and WPA Pre-Shared Key) in a plaintext form.  Even if RSA private keys are protected with a 
PEM passphrase when entered, they are still considered to be in plaintext form.
For the SX-500 to operate in FIPS 140-2 approved mode, the wireless security configuration must 
be set as follows:
Item
Required Setting
Wireless Encryption Mode
WPA2 (AES-CCMP)
Wireless Authentication
PSK or TLS or PEAP 
The SX-500 allows other security settings for interoperability in non FIPS 140 
environments.  However, use of the SX-500 with any settings other than those indicated 
above is not FIPS 140-2 compliant.   
Introduction
Silex
Page 5
Part Number 140-00188-210A