Silex Technology SX-500-1402 User Manual

Page of 72
Flow Control
In addition to the above parameters, the Serial Device Server allows you to configure numerous other 
capabilities.  These other capabilities provide you with the unparalleled flexibility to use the Serial Device 
Server on virtually any 802.11 or Ethernet network with a wide range of serial devices.  
Configuration Methods
There are two ways to configure the Serial Device Server:
Internal Web Pages (HTTP).  You can use any standard web browser to access the Serial Device 
Server internal web pages.  These web pages provide an easy-to-use graphical interface for 
configuring the Serial Device Server.  In order to use the internal web pages for the first time, you 
must assign the Serial Device Server IP address using some other method (for example, DHCP 
or arp/ping). This initial IP address assignment need only be done one time.
Internal Command Console.  The internal command console provides a sophisticated command 
line interface for advanced users to configure the Serial Device Server.  It can be accessed by 
connecting a serial cable to the serial port and using console mode switching as descried in 
chapter 4.  Once the IP address has been assigned, the internal command console can also be 
accessed via TELNET, or via  the internal web pages.  NOTE: when operating in a FIPS 140-2 
approved mode, the console is not available via the serial port.
If you have a Serial Device Server wireless model, Silex recommends that you temporarily plug 
the Serial Device into a wired Ethernet network during the configuration process.
 Although it is 
possible to configure the Serial Device Server with a completely wireless setup, it is much simpler to 
perform the process using a wired Ethernet connection.  This is primarily because the wireless security on 
most wireless networks prevents the addition of a new wireless device unless all security parameters are 
first entered into that device.  As a result, you must set up a temporary dedicated ad hoc wireless network 
in order to configure the Serial Device Server in a completely wireless environment (refer to the step 4 in 
the First Time IP Address Configuration section of this chapter for instructions on how to set up the Serial 
Device Server using a completely wireless Ad Hoc environment).  This is required when entering 
security encryption keys (RSA private key or WPA2-PSK).
Configuring the Serial Device Server using each of the above methods is described in the following 
sections of this chapter. 
Page 12
Silex
Configuring the Serial Device Server 
Part Number 140-00188-210A