Silex Technology SX-500-1402 User Manual

Page of 72
Chapter 6
Troubleshooting
If you have experience problems with the Serial Device Server, please check the following 
troubleshooting steps:
1. Make sure that you are getting power to the Serial Device Server.  The orange LED should be on 
solid if the proper power is being received.  If it is not on, check the power supply connections, 
and if possible, try a different Silex Serial Device Server power supply.
2. Make sure that you have a valid network connection.  
a. Make sure that your network is operating properly (that is, other devices should be able 
to communicate using the same hub, switch, or access point that the Serial Device 
Server is connected to).
b. If you are using hardwired Ethernet, the green LED should be lit or blinking.  If it is not, 
make sure that the cable is properly connected, and if possible, try a different Ethernet 
cable.
c. If you are using a wireless connection, both the yellow LED and green LED should be lit 
or blinking.  If they are not, double check your wireless settings.  The SSID and security 
parameters must exactly match the requirements of the access point in order for the 
Serial Device Server to communicate on an infrastructure wireless network.  If you are 
using Ad-Hoc mode, the Serial Device Server must have exactly the same SSID, security 
parameters, and RF channel as the other wireless device(s) on the network.
d. Make sure that you have a valid IP address, subnet mask and router address (check with 
your network administrator to make sure that you have the correct information).  You can 
check to see if the IP address information is correctly set by printing a test page (press 
the RESET pushbutton to send a test page to a printer or terminal connected to the serial 
port) or by using the PING command from a computer system connected to the network.
3. If you have a valid network connection and IP address, but you cannot communicate with your 
serial device, then:
a. Make sure that the settings of the serial port on your device exactly match the settings of 
the serial port of the Serial Device Server.  For example, if your device is set for 9600bps, 
8-bit characters, no parity, and RTS/CTS flow control, the Serial Device Server must also 
have these exact same settings.
Page 32
Silex
Troubleshooting
Part Number 140-00188-210A