Silex Technology SX-500-1402 User Manual

Page of 72
Command
Description
SET NW 
WPATRACE
Sets WPA trace level.  
This command is for internal diagnostic purposes only.  
The default value is 0 or disabled.
Format:
SET NW WPATRACE nn
NOTE: For FIPS 140-2 approved operation, this parameter must be 0
SH NW DISCONN
Displays the current value of the network disconnection timer
Sample output:
Disconnect Timer: 5
SET NW 
DISCONN
Sets the period of the network link disconnection watchdog timer.  In wireless 
infrastructure mode, this timer monitors the wireless link, and if the unit is not 
connected to an AP for the time specified, the unit is reset.
SET NW DISCONN nn
N = 0
watchdog timer is disabled
    1-255
watchdog timer period in minutes
The factory default value is 5 minutes.
This timer also controls a receive activity monitor when the wireless network link is 
connected.  If no packets are received during the time specified, and the link remains 
up, the unit will reset at the end of the time period.
SET NW RESET
This command stops, and then resets the wireless network interface.  This will 
effectively disassociate the unit from an access point if it is connected.  If the unit is 
in wireless infrastructure mode, the unit will then scan and attempt to reconnect to a 
suitable access point, if one is available.
Format:
SET NW RESET
ZEROKEYS
Zeroizes the module private key and WPA PSK key, as well as any temporary key 
values held in RAM.  The unit will then automatically perform a soft reset.  Note that 
if any wireless encryption is enabled, it will be impossible to connect to an access 
point until the necessary key information has been re-configured.
Port Commands
Table 12  Port Commands
Command
Description
SH PORT
Shows port parameters
Sample output:
Port     Q-Size     Type      Attributes
*S1        0       serial     115200 N 8 1 XON/XOFF 
CLEAR PORT S1 
JOB
Aborts the active job on the port.  
Console Commands
Silex
Page 46
Part Number 140-00188-210A