Intel S5000XAL User Manual

Page of 113
Appendix B: Sensor Tables 
Intel
®
 Server Board S5000PAL / S5000XAL TPS 
 
 Revision 
1.4 
Intel order number: D31979-007 
88 
Sensor 
Name 
Sensor 
Number 
System 
Applica-
bility 
Sensor Type
Event / 
Reading 
Type 
Event Offset 
Triggers 
Criticality 
Assert / 
De-assert 
Readable 
Value / 
Offsets 
Event Data 
Rearm 
Standby 
Watchdog  03h 
All 
Watchdog 2  
23h 
Sensor 
Specific 
6Fh 
Timer expired, 
status only 
Hard reset 
Power down 
Power cycle 
Timer interrupt 
OK As 
– 
Trig 
Offset 
A  X 
Platform 
Security 
Violation 
04h All  Platform 
Security 
Violation 
Attempt 
06h 
Sensor 
Specific 
6Fh 
Secure mode 
violation 
attempt 
Out-of-band 
access 
password 
violation 
OK As 
– 
Trig 
Offset 
A  X 
Physical 
Security 
05h Chassis 
Intrusion 
is chassis-
specific 
Physical 
Security 
05h 
Sensor 
Specific 
6Fh 
Chassis 
intrusion 
LAN leash lost 
OK 
As and De 
– 
Trig Offset 
FP Diag 
Interrupt 
(NMI) 
07h All  Critical 
Interrupt 
13h 
Sensor 
Specific 
6Fh 
Front panel NMI 
/ diagnostic 
interrupt 
Bus 
uncorrectable 
error 
OK As 
– 
Trig 
Offset 
A  – 
System 
Event Log 
09h All  Event 
Logging 
Disabled 
10h 
Sensor 
Specific 
6Fh 
Log area reset / 
cleared 
OK As 
– 
Trig 
Offset 
A  X 
Session 
Audit 
0Ah All  Session 
Audit
2Ah 
Sensor 
Specific 
6Fh 
00h – Session 
activation 
01h – Session 
deactivation 
OK As 
– 
As 
defined 
by IPMI 
A X