RESPONSE
REASON
INVALID
None
KERNERROR
None
The SET_PARAMETERS call
SET_PARAMETERS allows you to set the activity keypoint frequency for the CICS
region.
SET_PARAMETERS
DFHLGPAX [CALL,]
[CLEAR,]
[IN,
FUNCTION(SET_PARAMETERS),
[KEYPOINT_FREQUENCY(name4 | (Rn) ),]]
[OUT,
RESPONSE(name1 | *),
REASON(name1 | *)]
This command is threadsafe.
KEYPOINT_FREQUENCY(name4 | *)
specifies the activity keypointing frequency of the CICS region.
Permitted values are 0, or any integer between 200 and 65535 inclusive.
name4
The name of a 4-byte location that contains the new frequency value.
(Rn)
A register that contains the new frequency value.
RESPONSE and REASON values for SET_PARAMETERS:
RESPONSE
REASON
OK
None
EXCEPTION
OUT_OF_RANGE
DISASTER
None
INVALID
None
KERNERROR
None
Note: For more detail, refer to the explanation of RESPONSE and REASON in
Monitoring XPI functions
There are two XPI monitoring functions. These are the DFHMNMNX calls
MONITOR and INQUIRE_MONITORING_DATA.
DFHMNMNX calls cannot be used in any exit program invoked from any global
user exit point in the:
v
Dispatcher domain
v
Dump domain
v
Monitor domain
v
Statistics domain
v
Transient data program.
Chapter 3. The user exit programming interface (XPI)
361