Fujitsu RX900 S1 User Manual
90
Maintenance Manual
RX900
S1
Hard disk and solid state drives
6. Remove all CPUMEMRs, see
I
Before removing the CPUMEMRs, take a note on the installation
slot number for each CPUMEMR. Make sure that you reinstall the
CPUMEMR in the slot it was located before the SAS backplane
replacement.
slot number for each CPUMEMR. Make sure that you reinstall the
CPUMEMR in the slot it was located before the SAS backplane
replacement.
7. Unlock and remove all HDD/SSD modules, see
I
Before removing the HDD/SSD modules, take a note on the bay
number for each module. Make sure that you reinstall the module
in the bay it was located before the SAS backplane replacement.
number for each module. Make sure that you reinstall the module
in the bay it was located before the SAS backplane replacement.
6.4.3
Sliding the local service display outward
Figure 39: Sliding the local service display outward
Ê
Unlock the local service display (1).
Ê
Slide the local service display outward a few centimeters so that you have
free access (2).
free access (2).
/
0