Trap overview
5.3.14 PXRE traps (dec.mib)
MIB-OID: 1.3.6.1.4.1.36.2.15.21
This section lists PXRE traps in alphabetical order.
Trap name
ID
Meaning
Error class
cacheBatteryFailureTrap
7
A controller cache battery
has failed. Replace cache
battery or replenish charge.
has failed. Replace cache
battery or replenish charge.
major
cacheBattery
InformationTrap
InformationTrap
9
A controller cache battery
has
has
GOOD
state.
informational
cacheBatteryLowTrap
8
A controller cache battery
has
has
LOW
state. Replace
cache battery or replenish
charge.
charge.
minor
communication
FailureTrap
FailureTrap
12
Communication with the
subsystem has failed. The
Possible causes are data
path interruption,
communication LUN failure,
2 or more power supplies
failed, 2 or more fans failed,
temperature over limit, both
controllers failed.
subsystem has failed. The
Possible causes are data
path interruption,
communication LUN failure,
2 or more power supplies
failed, 2 or more fans failed,
temperature over limit, both
controllers failed.
critical
communicationInformatio
nTrap
nTrap
13
Communication with the
subsystem has recovered.
subsystem has recovered.
informational
controllerFailureTrap
14
The Secondary Controller
in the subsystem has failed.
Replace controller. Possible
causes are PCMCIA
memory card ejected,
controller physically
removed, actual hardware
failure.
in the subsystem has failed.
Replace controller. Possible
causes are PCMCIA
memory card ejected,
controller physically
removed, actual hardware
failure.
major
controllerInformationTrap 15
The Secondary Controller
in the subsystem has
recovered.
in the subsystem has
recovered.
informational
Table 37: PXRE traps