Fujitsu V6.00 User Manual

Page of 174
36
 
 ServerView 
Event 
Manager
iRMC S2 SEL Entries and SC2 MIB Traps
190017
’DIMM XY’: Memory 
replaced by spare 
memory
Memory module 
’DIMM XY’ in cabinet 
XY of server XY had 
failed and was 
replaced by a hot-
spare module.
2070 sc2TrapMem
ErrorModule
Replaced
19001A ’DIMM XY’: Memory 
module failed 
predicted
Memory module 
failure is predicted 
for module ’DIMM 
XY’ in cabinet XY of 
server XY.
2068 sc2TrapMem
ErrorModule
Prefail
19001F Memory: redundancy 
lost
Memory 
configuration in 
cabinet XY of server 
XY has lost 
redundancy.
2074 sc2TrapMem
Error
Redundancy
Lost
190035
’DIMM XY’: Memory 
module error
Memory module 
’DIMM XY’ in cabinet 
XY of server XY is 
failing. Too many 
errors have 
occurred.
2069 sc2Trap
MemError
ModuleFailing
190036
’DIMM XY’: Memory 
module failed 
(disabled)
340002
Housing opened
The front door or 
housing of cabinet 
XY was opened on 
server XY.
2110 sc2Trap
Intrusion
Assertion
340003
Housing closed
The front door of 
housing of cabinet 
XY was closed on 
server XY.
2111 sc2Trap
Intrusion
Deassertion
Error 
code
iRMC S2 SEL entry
Trap text
Trap 
no.
Trap name
Table 4: iRMC S2 SEL entry - SC2 MIB trap