Fujitsu BX600 S2 User Manual

Page of 173
PRIMERGY BX600 S2 Basic Unit
 149
15
Ventilation Concept
The basic unit is kept cool by two fan units (two fans each), and the fans in the 
power supply units (three fans in each PSU) and/or the fans in the PSU dummy 
unit(s) (two fans in each dummy).
The fan units are accessible from the rear of the system and contain two fans 
each.
Figure 95: PRIMERGY BX600 S2 basic unit: fan units
When a fan in a fan or power supply unit/PSU dummy module fails, the amber 
front identify LED (see 
) on the front panel blinks. You can 
find out which unit is defective by checking the fan status via the server 
management software 
ServerView
.
I
Even though the system can continue operating with a defective fan, the 
defective fan or power supply unit/PSU dummy module should be 
replaced as soon as possible.
For how to replace a power supply unit/PSU dummy module, see 
.
Due to the hot-swap architecture, replacement is also possible during operation.
FAN1
FAN2