Front or Rear Identify/Fault LED Blinks 
Amber
If the front or rear identify/fault indicator blinks amber (see 
) one of the malfunctions 
described below may have occurred in the system:
One of the power supply units fails
The PSU status LED is unlit and/or the PSU fan failure LED blinks green if there 
is an error in the corresponding power supply unit, e.g. (see also 
General failure (alert or fan #1 shutdown)
Overtemperature (any of the fans are not working properly in the corre-
sponding unit)
Overcurrent
Over- or undervoltage
The PSU is reaching the end of its life or is operating in an environment 
which exceeds the specified limits.
Ê
Check the PSU status and/or fan failure LEDs to identify the defective unit 
and exchange it (see 
One of the fans in the rear fan modules has failed
Even though the system can continue operating without one of the fans in the 
rear fan modules, you should:
Ê
Exchange the defective front fan module within a reasonable amount of time 
(see 
Switch blade fails
The failure LED of the switch blade lights up if there is a general error there.
Ê
Check the switch blade failure LEDs to identify the defective unit.
Ê
If the switch blade is still indicated as defective, exchange it (see 
).