10
Conversion standard PS to hot-
plug PS
V
CAUTION!
Observe the safety instructions in the chapter “Safety notes” on page 7 
et seqq. .
The standard power supply can be replaced by a hot-plug power supply. The 
hot-plug power supply consists of up to two power supply modules. The upgrade 
kit contains only one power supply module (for power supply redundancy the 
second power supply module must be additionally ordered).
The upgrade kit for the hot-plug power supply consists of the following parts:
PS cage with Power backplane (incl. power cables)
locking rail
one power supply unit
dummy cover (if only one power supply module is installed, you have to 
install the dummy cover in the second bay)
several screws
anti-tilt bracket
V
CAUTION!
After installing the hot-plug power supply the SDR (sensor data record) 
data base must be updated. For this sequence you need a BIOS flash 
diskette. This diskette contains the newest BIOS version, the BMC 
firmware and the SDR data.
Ê
Write a BIOS flash diskette by down loading the required data from 
the software pool under
Ê
Open the server as described in the chapter “Preparation” on page 13 et 
seqq. .
Ê
Disconnect all power cables from the system board and the drives (see the 
cabling plans in the Appendix).