CHAPTER 6 PCI Express card Hot Maintenance in Windows 
6.2 Common Hot Plugging Procedure for PCI Express cards 
121 
 
C122-E175-01EN 
 
In case of multi-function card, there are some cards that have same segment number, same bus number, and 
different function numbers. 
In this case, please perform Step.2 and No.3 of follows respectively. 
Addition procedure 
1.  Confirm physical location of added PCI card. 
2.  Add PCI card by using MMB Maintenance Wizard. [FE’s work] 
3.  Confirm added PCI card by using MMB Maintenance Wizard. 
Note 
FE will perform work of step 4 of replacement procedure and step 2 of addition procedure. 
6.2 
Common Hot Plugging Procedure for PCI Express cards 
This section describes the PCI Express card replacement procedure that does not involve additional steps 
(e.g., when a redundant application is not used). 
Note 
Insert the PCI Express card securely. 
6.2.1  Replacement procedure 
1.  Confirm the physical location, segment number, and bus number. 
a  Identify the mounting location of the PCI card to be replaced. 
See the figure in B.1 Physical Mounting Locations of Components to check the mounting location 
(board and slot) of the PCI card to be replaced. 
b  Confirm segment number and bus number. 
Open component information corresponded to confirmed physical location with step a by using MMB 
Web-UI. 
For this example, it is explained the method to confirm segment number and bus number of PCI 
slot#1 in PCI_Box#0. Select [System] – [PCI_Box] – [PCI_Box#0] in MMB Web-UI, and see 
Seg/Bus/Dev of PCIC#1 at PCI-Express Slots in [PCI_Box#0] information. 
‘Seg’ is segment number, and ‘Bus’ is Bus number in Seg/Bus/Dev information. 
This segment number and bus number is the information to confirm by using Device Manager.