Fujitsu 2000 SERIES User Manual

Page of 285
CHAPTER 6 PCI Express card Hot Maintenance in Windows 
6.4 FC Card Hot Plugging 
138 
 
C122-E175-01EN 
 
 
Note 
As the follow, right-click target device in Device Manager, if there are [Enable] in displayed menu, check 
[Enable]. 
(In case of [Disable], this work is not necessary) 
6.3.2  Hot plugging a non-redundant NIC 
 
This section describes the hot plugging procedure in networks without redundancy (a NIC is not incorporated 
into teaming). 
Replace NIC with 
’. 
6.3.3  NIC addition procedure 
 
Referring to ‘
’, add a NIC. 
6.4 
FC Card Hot Plugging 
For FC card hot plugging (replacement), you need to especially consider other matters in addition to the 
procedure described in ‘
’. 
The hot plugging of an FC card changes the WWN of the FC card if the WWN is set on an FC switch or RAID 
device (ETERNUS). For details on how to set the WWN again for a new card, see the respective device 
manuals. This section describes hot plugging of an FC card combined with ETERNUS MPD (multipath driver). 
It is required that the firmware version of new FC card is same as that of the FC card which had been 
replaced. If the firmware version of new FC card is coincident with that of the FC card which had been 
replaced (current firmware version), it is not necessary to update the firmware version of new FC card to 
current firmware version. 
If the firmware version of new FC card is not coincident with that of the FC card which had been replaced 
(current firmware version), update the firmware version of new FC card to current firmware version. 
For how to update the firmware version, see firmware update manual for fibre channel card. 
Notes 
FC cards at PCI Segment Mode are not valid. 
SAN boot paths are not valid. 
LTO library devices are not supported. 
Depending on the Windows specifications, if the FC card connection destination has a Page File or other 
such paging scheme, FC card hot plugging may not be supported.