Fujitsu 2000 SERIES User Manual

Page of 285
CHAPTER 1 Network Environment Setup and Tool Installation 
1.4 Maintenance LAN/REMCS LAN 
11 
 
C122-E175-01EN 
 
 
1.4 
Maintenance LAN/REMCS LAN
 
The MMB provides the following LAN ports for maintenance purposes. 
TABLE 1.6 Maintenance LAN/REMCS LAN 
Port
 
Description
 
Remarks
 
CE LAN
 
FST (CE terminal) port for use in maintenance work
 
100Base-TX, RJ45
 
REMCS LAN
 
For a connection with the REMCS Center (*)
 
100Base-TX, RJ45
 
*: For REMCS connection without using the management LAN 
The port-based VLAN function of the switching hub on the MMB blocks communication between the CE port 
and REMCS port. The following shows an outline of the maintenance LAN and REMCS LAN of the MMB. 
FIGURE 1.4 Maintenance LAN and REMCS LAN of the MMB 
 
The maintenance LAN is configured with Web-UI or CLI of the MMB. The subnet of the maintenance LAN 
must be separated from the other subnets such as one for the management LAN, the production LAN, etc. 
When the MMB is duplicated, the maintenance LAN can only access to the MMB on the active side. The NIC 
on the standby MMB is disabled. 
Remarks 
The active and standby MMBs in the PRIMEQUEST 2000 series server each have a CE terminal port used in 
maintenance and a LAN port for REMCS notification. Communication through the ports is enabled only on the 
active MMB and disabled on the standby MMB. A field engineer configures the maintenance LAN and 
REMCS LAN during system installation. 
1.5 
Production LAN
 
This section describes the configuration of the production LAN for the PRIMEQUEST 2000 series. 
1.5.1  Overview of the production LAN 
The IOU includes LAN ports for the production LAN. 
You can mount additional LAN cards in the PCI Express slots on the IOU and PCI_Box as needed, to use 
their ports for the production LAN.