System expansions
8.7.3
Installing a memory module
Ê
Populate the module you have just removed with the additional DIMMs (see 
the section “Installing DIMMs” on page 110).
If you are installing an additional module, this must be populated with the 
DIMMs before installation.
I
Install the module with the component side down.
Ê
Open the insert/eject levers of the module (by rotating them outward 90°) 
and slide the module into the slot guides of the empty slot until the levers 
engage with the flanges in front of the guides.
Ê
Simultaneously rotate the levers inward until they are flush with the edge of 
the module.
Ê
Mount the memory module cover (four screws) and the front bezel).
Ê
Use 
BIOS Setup
 to configure the system and if necessary specify the correct, 
expanded memory attributes.
8.8
RemoteView storage medium
For use 
RemoteView
, the remote test and diagnosis system, on the N800 servers 
an optional RemoteView IDE storage medium (chipDISK for RemoteView) is 
available.
The IDE storage medium is either pre-installed in the delivered server or is 
included in the delivery unit as a separate component. This depends of the way 
RemoteView
 has been ordered. The installation of the ChipDISK should only be 
executed by service technicians.
Usually the IDE storage medium is shipped with the 
RemoteView
/Diagnosis 
System pre-installed.
I
A supplementary order of a ChipDISK do not contains the pre-installed 
RemoteView
/Diagnosis System.