Fujitsu N800 User Manual

Page of 142
U41243-J-Z156-1-76
 89
System expansions
SCSI hard disk drives
8.2
SCSI hard disk drives
The server is equipped with four ultra 3-wide U160 SCSI hard disk drives. Each 
of the SCSI hard disk drives are mounted in slide-in modules. The drives are 
externally accessible at the front side of the server and connect to the SCSI 
backplane via the SCA (single connector attachment) interface. This allows that 
the drives can simply be inserted or pulled out (hot-plug). As part of the hot-plug 
implementation, a drive slide-in module with integrate heat dissipation is 
required. The drives are mounted in the slide-in module with fasteners and the 
slide-in module snaps into the chassis with a locking mechanism.
The hard disk drives can be controlled either by the dual onboard SCSI 
controller (default) or by a RAID controller (add-in board in a PCI slot). 
If a SCSI hard disk drive is operated on a RAID controller and belongs to a disk 
array operated with RAID level 1or 5, a hard disk drive can be swapped during 
operation (hot-swap). To swap a hard disk, you need a hard disk drive with the 
same or higher capacity. A rebuild on the new hard disk drive is performed 
automatically after the swap, provided the RAID controller is correctly 
configured. Refer to the information in the RAID controller manual.
I
If the hard disk drives are connected to the onboard-SCSI controller 
(default), the system must be turned off before exchanging a hard disk 
drive.
So that the storage capacity of the hard disk drive can be recognized at a glance 
when the hard disk drive is replaced, several prefabricated stickers with the 
storage capacities are provided with the server. Each hard disk drive (slide-in 
module) should bear a sticker indicating its capacity on the front. Should no 
suitable sticker be available, blank stickers for labeling are also provided. The 
stickers are color coded for easier identification.