Fujitsu RX200 S2 User Manual

Page of 307
177
PRIMERGY RX200 S2 User’s Guide    
Inst
allin
g I
nte
rn
al O
pti
ons
7
7.4.3 How to Install/Remove Memory Modules
This section explains how to install/remove memory modules. 
1
Turn the power off and remove the top cover.
2
Touch a metal part of the server to discharge static electricity. 
3
Install or remove memory modules.
• Installing
Insert a memory module properly into the memory slot. The levers close.
If the levers are not closed completely, push them with your fingers.
Check that the memory module is inserted all the way.
• Removing
Open the levers on both ends.
4
Check that the memory module is inserted all the way.
5
Install the top cover and return the server back into the rack.
6
Initialize the Extended System Configuration Data (ESCD).
pg.215) of the BIOS Setup Utility, set [Reset Configuration 
Data] to [Yes].
7
Store the BIOS settings.
• Make sure not to open the clips outward too quickly because the memory            
module may pop up, which could cause damage.
• An improperly engaged memory module could cause a fire. Do not insert the            
memory module on the wrong side.
Lever
Align notch