Fujitsu RX200 S2 User Manual

Page of 307
23
PRIMERGY RX200 S2 User’s Guide    
1
Overview
o USB connector (
)
Connects peripheral equipment conforming to the USB standard (2.0 or 1.1).
p 3.5-inch storage bay
Contains an internal hard disk unit.
q Inlet
AC power cables are plugged in.
1.3.2 Server (Rear View)
a LAN connector A (
)
An Unshielded Twisted Pair (UTP) cable is plugged in. For 1000Mbps connection, a cable 
conforming to category 5 enhanced is required.
The meanings of the two LED are shown in the table below.
The left LED may light green when no LAN cable is connected. This is not a failure. When a 
LAN cable is connected, the LED operates as shown in the table above. If the LED does not light 
or blink though a LAN cable is connected, the server may have a failure.
b LAN connector B (
)
This is a PCI connector. The applicable cable and meanings of the LEDs are the same as those for 
LAN connector A.
c Rear maintenance LED (
)
This LED lights amber when the server is not turned on (standby mode). When the server is 
turned on and the ServerView is installed, this LED lights amber during the logical drive 
initialization/rebuild of the onboard disk array controller. When an error is detected in the server 
components while the server is turned on, it also lights or blinks amber.
If this LED lights or blinks except for drive initialization or rebuild while the server is turned on, 
contact an office listed in the "Contact Information" section of the "Start Guide".
table: LAN Status
LED 
location
LED status
Connection status
Left
Lights green
Link is being established.
Blinks green
Data is being transferred.
Off
Link is not established.
Right
Lights amber
Connection is established at 1000Mbps.
Lights green
Connection is established at 100Mbps
Off
Connection is established at 10Mbps or 
the LAN is not connected.