Fujitsu RX200 S2 User Manual

Page of 307
263
PRIMERGY RX200 S2 User’s Guide    
9
O
p
eration
 a
nd 
Mainten
ance
■ Event Log Errors after Installation
After Windows installation, the following events may be displayed in Event Viewer. Check and perform 
the corrective action against the relevant event. 
■ Cannot Collect the Memory Dump
If the memory dump file cannot be created, perform the following procedures.
Correct the settings
If the memory dump cannot be collected, check the settings of the paging file and memory dump file.
For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (
Collect memory dump to other than the system drive
If the memory dump was set to be collected to the system drive (C:\), change the settings so that the 
memory dump can be saved to a drive other than the system drive.
For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (
If only the system drive exists, or if there is no free space in any of the drives, perform one of the 
following.
• Adding a hard disk
• Replacing with a larger hard disk
table: Error Events at Installation
ID
Description
Cause and corrective action
9
The device nnnn, did not respond 
during the timeout time.
This message may appear when an expansion card such as a 
RAID card or a SCSI card is installed. However, this is not a 
problem.
15
The device, nnnn, is not ready for 
access yet.
62
This computer is a domain PDC at the 
root of forest. Use the net command 
"net time /setsntp:<server name>" to 
configure it for synchronization from 
an external time source. 
Cause:
An NTP was selected as a component.
Corrective action:
ServerStart cannot configure the NTP server automatically due 
to the absence of items for specifying it. After OS installation, 
perform the following procedure to specify the time server. 
1. Start SNTP server operation on another machine. 
Assume that the SNTP server address is 
<172.22.78.246>. 
2. Enter the following at a command prompt. 
net time /setsntp:172.22.78.246
w32tm -s 172.22.78.246
1000
The user or computer name cannot be 
identified. The return value is "1722". 
Cause:
The primary DNS server address may be invalid or the server 
cannot be connected.
Corrective action:
Perform the following procedures to correct the DNS address 
in Internet protocol (TCP/IP) properties.
1. Right-click [My Network] and select [Properties].
2. Right-click [Local Area Connection] and click 
[Properties]. 
3. Click [Internet Protocol (TCP/IP)] and click 
[Properties]. 
4. Enter the correct DNS address in the [Primary DNS 
server] box.