Fujitsu RX200 S2 User Manual

Page of 307
287
PRIMERGY RX200 S2 User’s Guide    
9
O
p
eration
 a
nd 
Mainten
ance
9.10Maintenance & Notes
This section explains the details of the maintenance & Notes. 
9.10.1 Hard disk failure is detected
 If hard disk failure is detected during POST, the RX200 S2 on-board SCSI array controller stops with 
the following message.
If the controller stops with this message, insert the floppy disk "OnBoard RAID Utility" into the floppy 
disk drive of the system, and press the [Ctrl] key and [A] key at once to start up the system from the 
floppy disk. The utility automatically starts up. The following message appears on the utility.
 As shown here, if the message "Fatal Error happened. Please call support engineer." appears, do not 
start up the system. Please contact the maintenance person and system administrator.
Warning!: The array is degraded. Press [Ctrl] [A] to continue after 
insert Floppy Disk.
Background command progress status for controller 0...
IR Volume 1
  Current operation                       : None
  Volume ID                               : 0
  Volume status                           : Enabled
  Volume state                            : Degraded
  Physical disk I/Os                      : Not quiesced
curState: 1    prvState: 0
Previous Physical Disk States:
        ID0 : Failed  ID1 : Failed
Current Physical Disk States:
        ID0 : Online  ID1: Failed
Fatal ERROR happened. Please call support engineer
Background command progress status for controller 0...
IR Volume 1
  Current operation                       : None
  Volume ID                               : 0
  Volume status                           : Enabled
  Volume state                            : Degraded
  Physical disk I/Os                      : Not quiesced
curState: 1    prvState: 3
Previous Physical Disk States:
        ID0 : Online  ID1 : Failed
Current Physical Disk States:
        ID0 : Online  ID1: Failed
OK. You can boot system.
Please check HDD status after boot