Restoring Configuration Information
When you change ICU settings and exit the ICU, the newest configuration information is saved as the file name 
“SYSTEM.IMG”. When the configuration information has been destroyed or when you want to set up the system 
equipment again, you can use the SYSTEM.IMG file to restore the configuration information.
1.
Reset the setup contents of the system equipment to the factory-set status, or set up the system equipment once 
again.
If the configuration information has been destroyed, the contents of the Setup Menu must be returned to the 
factory-set status.
Before setting up the system equipment again, remove all boards other than those already installed as standard 
boards.
2.
Start the ICU.
3.
In the [ISA Configuration Utility] window, choose the [Advanced] menu.
4.
A screen that looks like the following is displayed. On that screen, choose [Load Image...].
5.
In the [Load Image File] window now displayed, choose “a:” from [Drives:] and “SYSTEM.IMG” from 
[Filename:]. The SYSTEM IMG file in ICU DISK2 in drive A restores the configuration information.
6.
Be sure to exit the ICU and then restart the system equipment.
If you keep on operation after an image file is called, a malfunction might occur.
Motherboard System Devices
PCI Card:  VGA Controller
PCI Card:  SCSI Controller
PCI Card:  Unknown Card
PCI Card:  IDE Controller
ISA Configuration Utility
File  Configure  View  Advanced  Help
Card Configured In System:
Add
Remove
Modify
View
Lord Image...
Locking Enabled
Lock/Unlock Card
Save Image
Save Image As...
Load Image File
a:
[   ]