Installation and configuration   47
Nortel Integrated Conference Bridge Service Implementation Guide
single-number access mode, configure only the single-access DN. In 
both cases, the BUI provides instructions about what to do next.
Installing the NTCW84JA I/O Panel Filter Connector for a Large System
For Large Systems, the standard IPE module I/O filtering is provided by 
the 50-pin filter connectors mounted in the I//O panel on the back of the 
IPE shelf. The filter connector attaches externally to the MDF cables 
and internally to the NT8D81AA backplane to the I/O panel ribbon cable 
assembly. For 100BaseTX TLAN operation, the standard I/O filter 
connector must be replaced with the NTCW84JA ITG Line-specific I/O 
filter connector for the slot occupied by the ICB card.
Note:  The NTCW84JA ITG-filter connector is not required on Small 
Systems or Succession 1000 systems. 
CAUTION: For Large systems manufactured between 1998-1999 and 
shipped in North America, IPE modules have the NT8D81BA 
backplane to I/O panel ribbon cable assembly with a non-removable 
filter connector. The NT8D81BA is compatible with a 10BaseT TLAN. If 
a 100BaseT TLAN is required, order the NT8D81AA Backplane to I/O 
panel ribbon cable assembly to replace it. Do not install the NTCW84JA 
filter connector onto the existing non-removable filter connector. 
CS 1000 configuration
Prior to installing any of the ICB hardware, configure the system 
software for the ICB card(s) through the system TTY terminal.
 
Summary 
The following summarizes the tasks for configuring the CS 1000:
1
LD 23 – Define the ACD DN assigned to the ICB card.
2
Define DNs using either:
LD 23 – Define ACD DNs and assign them to the ICB card.
or
LD 10 – Define Phantom TNs and forward them to the ACD DN 
assigned to the ICB card
.
3
LD 11 – Configure ICB ports as digital sets.
4
LD 23 – Configure the main DN for dual-card conferences.
5
LD 15 – Configure the CDR data if the feature Charge Account is 
used for billing.