Lucent Technologies 03.0.042.2 User Manual

Page of 16
Issue 1  July 2000 5
 
Change Descriptions
Change Descriptions
The following problems have been addressed and corrected in
 
DEFINITY 
Enterprise Communications Server (ECS), Release 8, Issue 3.0 (03.0.042.2).
1. When switching between PPP and X.25 type data modules, two copies of 
the 
Establish Connection field on the data module form appeared.
2. If 
Music on Hold for the class of restriction for an analog station was set to 
"no" and that station was bridged to a digital station, the analog station was 
blocked from flashing to transfer or conference a call.
3. Analog-originated calls coming in ISDN trunks from the NTT Network did 
not disconnect properly when the PBX sent an ALERT message followed 
by a DISCONNECT message.  An administrable option on page 2 of the 
trunk group form now allows the PBX to send a CONNECT message 
before sending the DISCONNECT message, for analog-originated calls 
that come in on trunks in that trunk group.  Thus, analog originated calls 
coming in ISDN trunks (so administered) from the NTT Network will 
disconnect gracefully.
4. The system could go into overload if a sufficiently large number of calls 
were executing a poorly written vector (i.e., a vector with a loop not 
containing a wait step).  Time breaks will be inserted in vector processing 
more frequently now, when the system experiences high processor 
occupancy.
5. Basic Rate Interface (BRI) trunks failed to make an outgoing call, if the 
network did not allocate a Terminal Endpoint Identifier (TEI) on the 
previous outgoing call attempt.
6. When selecting “help” in the 
AUDIX Name or Messaging Server Name 
fields on the hunt group form, the help message directed the user to a 
form which was no longer supported.  This occurred if no “audix” or “msa” 
nodes were specified on the node-names form.  This help message now 
directs the user to the appropriate form.
7. Attendent Direct Extension Selection (DXS) access failed if the ARS 
shortcut was enabled.