Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-147
Installing a 3150/3170 Channel Service Unit 
6
Figure 6-58.
DS1 Converter Connections Using Double-Headed cable
1. Port carrier
2. DS1 converter connector
3. 50-pair female connector to DEFINITY System
4. 14-Inch (35.57 cm) “Y” cable
5. 50-Pin Male/50-pin female double-headed  
connector cable
6. Quad cable (with 50-pin male connector) connects 
to the channel service unit.
Table 6-14.
“Y” cable Lengths (DS1 converter Only)
Length 
(in/cm)
Description
Comcode
14/35.5 
TN1754 to adjacent expansion interface circuit pack or 
TN573B switch node interface circuit pack in same carrier
 847245750
70/177.8
TN1754 to expansion interface circuit pack or switch node 
interface in another carrier
847245778
14/35.5
TN1754 to fiber optic transceiver (DC-powered cabinets only). 
This cable is for intercabinet cabling only.
847245777
14/35.5
TN1754 to adjacent TN570/B/C expansion interface circuit 
pack 
847747741
cydf010 RPY 090597
20
19
16
17
18
15
14
13
12
11 10
09
08
07
06
05
04
03
02
01