Adding or Removing Cabinet Hardware
6-121
Add a Switch Node Carrier (High or Critical Reliability)
6
Reseat DEFINITY LAN Gateway System
1. Reseat the LAN Gateway assembly into its backplane connectors.
Reseat DEFINITY AUDIX System
1. Reseat the AUDIX assembly to its backplane connectors.
Power Up System
1. At each EPN, if present, set the main circuit breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs the level 4 rebooting process, loading the system
program and default or current translations from the disk. Rebooting takes
5 to 11 minutes.
5 to 11 minutes.
NOTE:
Ignore alarms for now.
4. Type reset system 4 and press
Enter
to copy the translations from
removable media to memory.
5. Clear any alarms.
6. Type save translation [both] and press
Enter
if translation changes were
made in Step 8 above.
7. Type restore disk [both] full and press
Enter
to copy the translations from
removable media to disk.
8. After the system reboot is finished and all trouble cleared, verify that the
EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores
the system to the normal operating mode.
the system to the normal operating mode.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select
Maintenance.
3. Select
Reset System from the Maintenance menu.
4. Select
Restart System from the Reset System menu.