Nortel Networks 3500 User Manual

Page of 342
Operation, administration, and maintenance (OAM) features   2-173
Planning and Ordering Guide—Part 1 of 2   NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
 provides a sample of the output of RTRV-EQPT 
command when performed with different STX and VTX-series circuit packs.
TL1 event exerciser
With one TL1 command (
RTRV-NE-AOMSG:[TID]:[ALL]:CTAG
) in Site 
Manager’s TL1 Command Builder, a UPC level 4 account user can request an 
output of all possible TL1 autonomous messages (including alarms and 
events). The output has exact wording for autonomous messages and is 
available at both the SPx and NPx.
Note:  Requesting an output from the SPx will generate all autonomous 
messages possible from the SPx. Requesting an output from the NPx will 
generate all autonomous messages possible from the NPx.
Execution of the TL1 command will not impact traffic currently on the system 
and will not impact OAM performance on a separate network element.
TL1 event / log feature
Network elements will track configuration changes, unsuccessful TL1 
command attempts, and shelf inventory changes. Autonomous events 
(DBCHG, LOG, and INVENTORY) display after the TL1 return code. A file 
containing the history of all three event types is updated with the latest 
DBCHG, LOG, and INVENTORY events each time an event occurs. This file 
will survive restarts and circuit pack pulls and is retrievable by the user. The 
DBCHG and LOG events apply to both the network processor and shelf 
processor circuit packs.
Note 1:  All information is stored regardless of whether broadcasting is 
provisioned as ‘ON’ or ‘OFF’.
Note 2:  Event broadcasting is set to ‘OFF’ by default.
Table 2-35
CLX RTRV-EQPT Behaviour
Card in Slot 13 and 14
RTRV-EQPT Output
None
“CLX-13::CTYPE=VTX:OOS-AU, UEQ”
“CLX-14::CTYPE=VTX:OOS-AU, UEQ”
VTX-48
“CLX-13::CTYPE=VTX48, PEC= ...”
“CLX-14::CTYPE=VTX48, PEC= ...”
VTX-48e
“CLX-13::CTYPE=VTX48e, PEC= ...”
“CLX-14::CTYPE=VTX48e, PEC= ...”
STX-192
“CLX-13::CTYPE=STX192, PEC= ...”
“CLX-14::CTYPE=STX192, PEC= ...”