Nortel Networks 3500 User Manual

Page of 342
Hardware feature descriptions   3-55
Planning and Ordering Guide—Part 1 of 2   NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
Equipping rules 
The VTX-48 circuit pack is a double-width circuit pack that can be installed in 
slot 13 and slot 14 of the OPTera Metro 3500 shelf.
Note 1:  The VTX-48 circuit pack (NTN414AA) only supports the OC-48 
line rate in slots 11 and 12.
Note 2:  The OC-12 line rate is supported in slots 11 and 12 only if slots 
13 and 14 are equipped with VTX-48e circuit packs (NTN414AB or 
NTN414AH).
Alarm LED definitions 
The following table provides a list of LEDs on the STX-192 circuit packs.
VTX-48e circuit pack
(NTN414AB, NTN414AH)
The VTX-48e circuit pack supports the use of both OC-12 and OC-48 line rate 
in slots 11 and 12.
VTX-48e circuit packs provide monitoring and control for provisioning, 
cross-connect management, shelf timing generation, and synchronization 
messaging. The internal clock quality is Stratum 3 (ST3). VTX-48e circuit 
packs also support DS1 ESF BITS synchronization status messaging.
VTX-48e circuit packs manage synchronization and shelf bandwidth as 
separate entities. For example, if there is a synchronization failure on the 
VTX-48e circuit pack in slot 13, and a bandwidth management functional 
block failure on the VTX-48e circuit pack in slot 14, the system can still carry 
traffic and provide synchronization timing to other network elements.
VTX-48 equipment operates in 1+1 redundant mode to provide cross-connect 
and clock distribution functions for OPTera Metro 3500. It is always 
autoprovisioned and cannot be deleted. Only one of the two VTX-48e circuit 
packs can be taken out of service at a time.
LED name
Color
Description 
Status (top)
red 
Circuit pack failure 
Status (bottom)
green 
VTX in an in-service state
Pri Fail
yellow 
Loss of primary timing reference signal 
Sec Fail
yellow 
Loss of secondary timing reference signal