Nortel Networks 3500 User Manual

Page of 342
Hardware feature descriptions   3-59
Planning and Ordering Guide—Part 1 of 2   NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
Equipping rules 
The NPx must be installed in slot 16. See 
 for operational 
temperature ranges.
Alarm LED definitions 
The following table provides a list of LEDs on the NPx circuit pack.
ILAN interface
(NTN425AA)
The ILAN circuit pack (NTN425AA) provides the Ethernet hubbing 
functionality required to interconnect OPTera Metro 3000 shelves. The ILAN 
circuit pack provides a low cost solution to Ethernet connectivity between 
OPTera Metro, OC-48 Classic Phoenix SP, OPTera Connect DX and OPTera 
Long Haul OPCs and the OPTera Connect HDX as well as the capability to 
daisy-chain up to 16 shelves. The ILAN interface gives the user access to 
ILAN ports 1 and 2 on the LOAM.
Note:  The ILAN interface circuit pack does not give the user access to 
COLAN ports.
Equipping rules
The ILAN circuit pack must be inserted in slot 16. See 
for operational temperature ranges.
OC-192 optical interface circuit pack
(NTN445CB, DA)
The main transport OC-192 circuit pack operates at an OC-192 line rate (9.953 
Gbit/s for IR and 10.709 Gbit/s for LR and DWDM). The OC-192 circuit pack 
can be installed in slots 11 and 12 in a UPSR, 1+1 linear system and BLSR. In 
the 1+1 linear protection scheme, OC-192 circuit packs can be provisioned in 
either unidirectional or bidirectional mode. See 
 fo
operational temperature ranges.
 for the OC-192 optical wavelengths and line rates supported for 
the transmit and receive optical circuit packs.
LED 
Color
Description 
Status
Red 
Circuit pack failure, reset or insertions
Yellow
Facility failure
Active
Green
In service