Nortel Networks 3500 User Manual

Page of 342
3-66   Hardware feature descriptions
OPTera Metro 3500 Multiservice Platform    NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
Section trace for OC-48
OPTera Metro 3500 supports section trace capability for OC-48 services. 
Section trace provides a diagnostic tool that can determine installation and 
commissioning problems such as misconnected optical fibers. Section trace 
occupies the J0 SONET byte (formerly known as the C1 byte to indicate the 
STS-1 ID) of the section overhead. Section trace is injected at the transmit end 
of a section and extracted at the receive end where it can be checked against an 
expected section trace value.
Section data communication channel (SDCC)
An OC-48 line carries a DCC channel that can be edited, provisioned, and 
deprovisioned.
Note 1:  The maximum number of simultaneous SDCC-provisionable 
ports on an OPTera Metro 3500 shelf is 34 (the shelf must be equipped with 
eight unprotected OC-3x4 circuit packs in slots 3 through 10, and a 
protected pair of OC-48 circuit packs in slots 11 and 12).
Note 2:  For Nortel Networks interworking and multi-vendor network 
scenarios, DCC interoperability can be achieved with the appropriate 
provisioning. See Optical Networks Data Communications Network 
Planning Guide
, NTR710AM.
Alarm LED definitions
The following table lists the OC-48 interface circuit pack LEDs.  
Equipping rules
The OC-48 optical interface circuit pack can be installed in slots 11 and 12. 
See 
 for operational temperature ranges.
Note:  Requires the shelf to be equipped with VTX-series circuit packs in 
slots 13 and 14.
An OPTera Metro 3500 network element with a protected OC-48 line rate 
requires two OC-48 circuit packs in slots 11 and 12 of each shelf.
LED 
Color 
Description
Status (top)
Red 
Circuit pack failure
Yellow Loss 
of 
signal 
Status (bottom)
Green 
In service and carrying traffic