3-84   Hardware feature descriptions
OPTera Metro 3500 Multiservice Platform    NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
Note 2:  For Nortel Networks interworking and multi-vendor network 
scenarios, DCC interoperability can be achieved with the appropriate 
provisioning. See Optical Networks Data Communications Network 
Planning Guide
, NTR710AM.
Alarm LED definitions 
The following table provides a list of the EC-1x3 circuit pack LEDs. See 
 for the EC-1x3 circuit pack faceplate layout showing 
the location of the LEDs.  
EC-1x12 circuit pack
(NTN436DA)
The EC-1x12 circuit pack receives and transmits twelve EC-1 signals from 
external equipment and provides accessibility to VT1.5/s or STS-1s within the 
network element. This circuit pack is fully bidirectional. The facility signal 
attributes for an EC-1x12 circuit pack facility are provisionable. 
Equipping rules 
Connectivity for the 12 EC-1 signals at each slot is through the BNC 12-Port 
Front I/O module (NTN452JA) on the OPTera Metro 3500 Shelf 
(NTN476DA). On the OPTera Metro 3500 Universal Shelf (NTN476AH) you 
must use the BNC 12-Port Front Enhanced I/O module (NTN452JH) or the 
BNC 12-Port Rear I/O module (NTN452KA).
The EC-1x12 circuit pack can be installed in slots 3 through 10. EC-1x12 
circuit packs are installed in pairs. The first EC-1x12 circuit pack of the pair is 
installed in an odd slot. The second EC-1x12 circuit pack of the pair is installed 
in the adjacent even slot. The second EC-1x12 circuit pack functions as the 
protection EC-1x12 circuit pack for the working circuit pack in the odd slot. 
The maximum number of working EC-1x12 circuit packs that can be inserted 
in a shelf is four. 
 for operational temperature ranges.
Note 1:  If there is a 1-28 DS1 I/O module installed, and if slots 5 and 6 are 
not equipped with DS1 mappers, you may not install EC-1x12 circuit 
packs in slots 5 or 6 (there is not enough room for slot 5 or slot 6’s BNC 
I/O modules).
LED 
Color 
Description
Status Red  Circuit 
pack 
failure 
Active
Green 
Circuit pack equipment is active and at least one 
EC-1 line facility is in service with at least one 
cross-connect
LOS(1-3)
Yellow
Loss of signal on the port