3-90   Hardware feature descriptions
OPTera Metro 3500 Multiservice Platform    NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
The maximum number of working DS3x12 / DS3x12e mappers that can be 
inserted in a shelf is four.
 for operational temperature ranges.
Note 1:  Mixing a DS3x12 mapper with a DS3x12e mapper as a protected 
pair will result in the protected pair to behave as 2 DS3x12 circuit packs. 
Additional path PMs and alarms supported with the DS3x12e are not 
available when circuit packs mixed. 
Note 2:  If there is a 1-28 DS1 I/O module installed, and if slots 5 and 6 are 
not equipped with DS1 mappers, you may not install DS3x12 or DS3x12e 
circuit packs in slots 5 or 6 (there is not enough room for slot 5 or slot 6’s 
BNC I/O modules).
Note 3:  If there is a 29-56 DS1 I/O module installed, and if slots 7 and 8 
are not equipped with DS1 mappers, you may not install DS3x12 or 
DS3x12e circuit packs in slots 7 and 8 (there is not enough room for slot 7 
or slot 8’s BNC I/O modules).
Note 4:  If there is a 29-84 DS1 I/O module installed, and if slots 7 through 
10 are not equipped with DS1 mappers, you may not install DS3x12 or 
DS3x12e circuit packs in slots 7 through 10 (there is not enough room for 
slot 7 through slot 10’s BNC I/O modules).
Alarm LED definitions 
The following table provides a list of the DS3x12 / DS3x12e mapper LEDs. 
See 
 for the DS3x12 and DS3x12e mapper faceplate 
layout showing the location of the LEDs. 
DS3VTx12 mapper
(NTN435FA)
Each of the 12 ports of the DS3VTx12 mapper receives a channelized DS3 
signal and demultiplexes it into 28 DS1s. The DS1s are mapped into VT1.5s 
and carried off the circuit pack to the VTX-series circuit packs where they are 
cross-connected into any of the supported transport or tributary circuit packs. 
This mapper is fully bidirectional.
For more information about channelized DS3 service and the DS3VTx12 
mapper, see 
.
LED 
Color 
Description
Status
Red Circuit 
pack 
failure 
Active
Green 
DS3x12 equipment is active and at least one DS3 
line facility is in service with at least one 
cross-connect
LOS (1-12)
Yellow
Loss of signal on the port