Raritan Computer SX8 User Manual
4 D
OMINION
SX
I
NSTALLATION AND
O
PERATIONS
M
ANUAL
4. Connect the female end of the external power cord to the back of the chassis.
5. Connect the male end of the external power cord to the power supply outlet. Power ON the Dominion
5. Connect the male end of the external power cord to the power supply outlet. Power ON the Dominion
SX unit.
Note: The unit will perform a hardware and firmware self-test, indicated by the green light on the back of
the chassis, and then start the software boot sequence. The boot sequence takes approximately 30-60
seconds, and is complete when the green light illuminates and remains on.
the chassis, and then start the software boot sequence. The boot sequence takes approximately 30-60
seconds, and is complete when the green light illuminates and remains on.
6. Each unit comes with a certain set of configuration defaults henceforth referred to as Factory Reset
Mode. The default network settings for this mode are:
Internet Address (IP)
192.168.0.192
Gateway Address
192.168.0.192
Subnet Mask
255.255.255.0
Port Address
51000
Figure 3 Default Settings for Factory Reset Mode
7. Ensure that your installation computer can communicate with IP address 192.168.0.192. First, verify
that the installation computer has the route for 192.168.0.192:
a. On the command line interface of the installation computer, enter the command route print.
b. If 192.168.0.192 is on the gateway list, proceed to the next step. Otherwise, add 192.168.0.192 to
a. On the command line interface of the installation computer, enter the command route print.
b. If 192.168.0.192 is on the gateway list, proceed to the next step. Otherwise, add 192.168.0.192 to
the gateway list: type the following commands into either a DOS or UNIX command line interface
on the installation computer where your browser is running:
i. On a Windows NT/95/98/2000 system: route add 192.168.0.192 <client_host IP address>
Example:
route add 192.168.0.192 15.128.122.12
ii. On a UNIX (incl. Sun Solaris) system: route add 192.168.0.192 <client_host IP address> -
on the installation computer where your browser is running:
i. On a Windows NT/95/98/2000 system: route add 192.168.0.192 <client_host IP address>
Example:
route add 192.168.0.192 15.128.122.12
ii. On a UNIX (incl. Sun Solaris) system: route add 192.168.0.192 <client_host IP address> -
interface
Example:
route add 192.168.0.192 15.128.122.12 -interface
route add 192.168.0.192 15.128.122.12 -interface
8. On the command line interface, type: ping 192.168.0.192.
a. If this command successfully produces a reply from the Dominion SX unit, please proceed to step
10.
b. If this does not produce a reply, verify that the default IP address is entered correctly and there is a
route to that IP address.
9. Use the installation computer to connect to the unit, typing the factory default IP address
192.168.0.192 in the installation computer Web browser’s address line. Once you have reached the
unit’s initial configuration screen, proceed to the Initial Software Configuration section that follows.
unit’s initial configuration screen, proceed to the Initial Software Configuration section that follows.