Perle Systems 5500161-40 User Manual

Page of 424
Pinouts and Cabling Diagrams  371
EIA-232 Cabling Diagrams
EIA-232 Cabling Diagrams
This section shows how to create EIA-232 cables that are compatible with the Device Server.
Terminal DB25 Connector
The following diagrams show how the null modem cable should be configured when connecting to a 
terminal DB25.
DB25 Male
2 (TxD)
3 (RxD)
3 (RxD)
2 (TxD)
4 (RTS)
5 (CTS)
5 (CTS)
4 (RTS)
6 (DSR)
20 (DTR)
7 (GND)
7 (GND)
20 (DTR)
6 (DSR)
DB25 Female
3 (TxD)
3 (RxD)
2 (RxD)
2 (TxD)
5 (RTS)
5 (CTS)
4 (CTS)
4 (RTS)
20 (DSR)
20 (DTR)
7 (GND)
7 (GND)
6 (DTR)
6 (DSR)
IOLAN DS1
DB25 (DTE)
Terminal DB25
(DTE)
IOLAN DS1
DB25 (DCE)
Terminal DB25
(DTE)